3X1.0sqmm Stranded Smoke Detector Control Cable

Product Details
Customization: Available
Type: Insulated
Conductor Type: Solid
Still deciding? Get samples of US$ 50/Meter
Request Sample

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
6000 square meters
Management System Certification
ISO14001:2015
  • 3X1.0sqmm Stranded Smoke Detector Control Cable
  • 3X1.0sqmm Stranded Smoke Detector Control Cable
  • 3X1.0sqmm Stranded Smoke Detector Control Cable
  • 3X1.0sqmm Stranded Smoke Detector Control Cable
  • 3X1.0sqmm Stranded Smoke Detector Control Cable
  • 3X1.0sqmm Stranded Smoke Detector Control Cable
Find Similar Products

Basic Info.

Model NO.
LLT-FR 310A
Application
Overhead, Underground
Conductor Material
Copper
Insulation Material
Silicone Rubber
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
Lpcb
Brand
Llt
Lead Time
Within 15 Days
Costomization
Available
Transport Package
Wooden Reel
Specification
2C x (1.0 mm-2.5 mm)
Trademark
LLT
Origin
Shenzhen, China
HS Code
8544492100
Production Capacity
400, 000 Meter Per Day

Product Description

2*1.5 LPCB fire proof cable
Specifications
1.Type: power cables 
2.Use: fire alarm systems 
3.Interface type: 2-core/3-core/4-core
4.Feature: anti-fire to remain circuit
Standards
We use the best quality of material to achieve the best performance in LPCB standards: 
BS 7629-1, EN 50200, BS 5839-1 clause 26.2d, BS 6397:
Fire testing:
1. EN 50200:2006. Method of test for resistance to fire of unprotected small cables for use in 
emergency circuits. European committee for electro technical standardization, brussels, 2006
2. BS 7629-1:2008. British standard specification for 300/500V fire resistant cables having low
emissions of smoke and corrosive gases when affected by fire. British standards institution, London,
2008.
3. BS 6387:1994. Performance requirements for cables required to maintain circuit integrity under fire
conditions. British Standards Institution, London, 2013.
C - Resistance to fire at 950ºC for 3 hours
W - Resistance to fire and water at 650ºC for 30 minutes and
Z - Resistance to fire and mechanical shock at 950°C for 15 minutes
4. BS 5839-1:2013 Clause 26.2d states 'standard fire resisting cables' should meet the PH30 classification
 when tested in accordance with EN 50200 and additionally the 30 minute survival time when tested in
 accordance with Annex E of that standard.

3X1.0sqmm Stranded Smoke Detector Control Cable  
Brand name: LLT
Model number: FR 1831
Use: fire alarm systems
Type: power cables
Interface type: 2core/3core/4core
Section area: 1.0mm2 /1.5mm2/ 2.5mm
Conductor: bare copper
Insulation: silicone E12
Screen: Mica tape with Al foil & fiberglass
Sheath: LSZH polyolefin
Feature: anti-fire
Price: get latest price
Packaging details: standard packing
Supply ability: available

3X1.0sqmm Stranded Smoke Detector Control Cable
Cable Nos. of Cores&Section (mm2) Rated Voltage Uo/U Conduct or size(mm2) Pure copper conductor type Number of Cores Insulation material type Binding Tape
Overall diamater(mm)
min    max
Sheath material type Select color
LLT-FR 210A 2x1.0 300/500 1 Class1 2+E EI2 AL/Mica tape 7.2 8.2 LTS3 red/white
LLT-FR 215A 2x1.5 300/500 1.5 Class1 2+E EI2 AL/Mica tape 8.5 9.5 LTS3 red/white
LLT-FR 225A 2x2.5 300/500 2.5 Class1 2+E EI2 AL/Mica tape 9.5 10.5 LTS3 red/white
LLT-FR 310A 3x1.0 300/500 1 Class1 3+E EI2 AL/Mica tape 7.2 8.2 LTS3 red/white
LLT-FR 315A 3x1.5 300/500 1.5 Class1 3+E EI2 AL/Mica tape 8.5 9.5 LTS3 red/white
LLT-FR 325A 3x2.5 300/500 2.5 Class1 3+E EI2 AL/Mica tape 10.5 11.5 LTS3 red/white
LLT-FR 410A 4x1.0 300/500 1 Class1 4+E EI2 AL/Mica tape 8 9 LTS3 red/white
LLT-FR 415A 4x1.5 300/500 1.5 Class1 4+E EI2 AL/Mica tape 9.5 10.5 LTS3 red/white
LLT-FR 425A 4x2.5 300/500 2.5 Class1 4+E EI2 AL/Mica tape 11.5 12.5 LTS3 red/white
... ... ... ... ... ... ... ... ... ... ... ...
 
Cable Nos. of Cores&Section (mm2) Rated Voltage Uo/U Conduct or size(mm2) Pure copper conductor type Number of Cores Insulation material type Binding Tape
Overall diamater(mm)
min    max
Sheath material type Select color
LLT-FR 210B 2x1.0 300/500 1 Class1 2+E EI2 PET Mylar+AL foil 7.2 8.2 LTS3 red/white
LLT-FR 215B 2x1.5 300/500 1.5 Class1 2+E EI2 PET Mylar+AL foil 8.5 9.5 LTS3 red/white
LLT-FR 225B 2x2.5 300/500 2.5 Class1 2+E EI2 PET Mylar+AL foil 9.5 10.5 LTS3 red/white
LLT-FR 310B 3x1.0 300/500 1 Class1 3+E EI2 PET Mylar+AL foil 7.2 8.2 LTS3 red/white
LLT-FR 315B 3x1.5 300/500 1.5 Class1 3+E EI2 PET Mylar+AL foil 8.5 9.5 LTS3 red/white
LLT-FR 325B 3x2.5 300/500 2.5 Class1 3+E EI2 PET Mylar+AL foil 10.5 11.5 LTS3 red/white
LLT-FR 410B 4x1.0 300/500 1 Class1 4+E EI2 PET Mylar+AL foil 8 9 LTS3 red/white
LLT-FR 415B 4x1.5 300/500 1.5 Class1 4+E EI2 PET Mylar+AL foil 9.5 10.5 LTS3 red/white
LLT-FR 425B 4x2.5 300/500 2.5 Class1 4+E EI2 PET Mylar+AL foil 11.5 12.5 LTS3 red/white
... ... ... ... ... ... ... ... ... ... ... ...

3X1.0sqmm Stranded Smoke Detector Control Cable 

LLT Fire resistant cable aims to be customer's first choice to keep safe from the fire situation, by designing, developing the latest technology products with high quality and reliability. Your requirements in fire protection in any commercial or industrial setting will be met. LLT LPCB approved cables will achieve the best performance. Best material makes the best quality, choose LLT, and choose a safe life. LLT has been approved ISO 9001, UL, VDE, RoHS.

3X1.0sqmm Stranded Smoke Detector Control Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier